Titan – Example Scenario 1.4: Provide a PLC device with an Ethernet port with Internet access. WiFi devices will be able to access the Ethernet device but Internet access will be blocked
Details of the example scenario: We have a PLC device with an ETH port which we want to provide with Internet access to send data to the Cloud. The PLC has a local IP address of 192.168.1.1 Several tablets will also connect to the router via WiFi (DHCP) which will need to be able to connect to […]
Titan – Example Scenario 1.3: Provide Internet access to a device with an Ethernet port and to several devices with WiFi connectivity
Details of the example scenario: We have a device with ETH port which we want to provide with Internet access to send data to the Cloud. The Ethernet device has a local IP address of 192.168.1.70 We should also be able to provide several other WiFi devices (tablets) with Internet access. These devices will connect to […]
Titan – Example Scenario 1.2: Provide Internet access and remotely connect an IP camera with an Ethernet port
Details of the example scenario: We have an IP camera with Ethernet port that we want to provide with Internet access. The camera has a local IP address of 192.168.1.70 The IP camera has an internal webserver that we can use to access the video that is being recorded. The TCP port used by the camera is […]
Titan – Example Scenario 1.1: Provide a PLC device with an Ethernet port with access to the Internet
Details of the example scenario: We have a PLC device with ETH port that we want to provide with Internet access in order to send data to the Cloud. The PLC has a local IP address of 192.168.1.70 We need to be able to access the router’s configuration remotely in the standard TCP port 80 SIM […]